Brief and design basis
Building use, occupancy, design conditions, the codes the project must meet and the responsibility split — agreed and written down before any calculation is run.
Mechanical, electrical, plumbing and fire protection designed together, calculated by engineers and drawn straight into a coordinated model — so the design that is approved is the design that fits.
MEP engineering design
A duct sized without its route is a size that will change. We size and route together, in the model, so the design that leaves us has already been tested against the ceiling void, the structure and the other services. That removes the most expensive cycle in building services: the design that is correct on paper and impossible on site.
Every calculation states its method, inputs, design conditions and assumptions. A reviewer at the client, the contractor or the authority can follow it without asking us what we meant — which is what lets a design move through approval without avoidable comments.
Design is carried out by BIMRACE's qualified engineers within the design responsibility written into the appointment. Where a jurisdiction requires a locally licensed engineer to sign, stamp or submit drawings and calculations, that engineer of record does so; we prepare and support the submission. Authority approvals are obtained by the appointed professionals.
Deliverables
Any of these can be appointed on their own or combined. Nothing here depends on buying the intelligence layer, which is not for sale in any case.
Catalogue scope
The full list from the BIMRACE service catalogue. Each item can be included or excluded in a proposal; the code is the one used in our scope documents.
How it runs
Sequence is not a formality on this kind of work. Most of the expensive rework we are asked to fix was produced by doing step four before step two.
Building use, occupancy, design conditions, the codes the project must meet and the responsibility split — agreed and written down before any calculation is run.
System options compared for space, energy, capital and maintenance cost, with plant and riser space reserved early so the architecture can accommodate them.
Loads, flows and sizes calculated to the stated method, with assumptions listed on the calculation rather than buried in it.
The design is drawn directly in Revit, so sizes, routes and equipment data live on the elements and coordination starts from the design, not after it.
Federated clash and clearance checks against architecture, structure and the other services; an independent engineering review before issue.
Design drawings, calculations, schematics and schedules issued under revision control, with support through tender, approvals and construction queries.
What we need to start
Missing any of these is survivable. Not knowing which of them are missing is not, so we establish it at enquiry stage rather than at forty per cent.
AI & automation
AI is used throughout our delivery workflow, and an engineer reviews every output. Every line carries its real status.
Scope boundary
Published because a scope boundary discovered at month three is a dispute, and the same boundary stated at enquiry stage is just information.
Request a quote
Tell us the building, the stage and what you need. An engineer replies within two working days with approach, deliverables and a fee basis.
Quote request received
Have drawings ready? Use the full enquiry form to attach them.
What a useful quote needs. Building type and approximate area, the disciplines, the project stage, and which drawings or models exist. If you have them ready, the full enquiry form takes file uploads.
NDAs. We sign before drawings or models are shared, as a matter of course.
FAQ
Both. We provide MEP engineering design — calculations, system design, schematics and design drawings — and BIM modelling, coordination and documentation. Design is delivered within the design responsibility agreed in the appointment.
The ones the project names. Typical examples are ASHRAE and CIBSE guidance for HVAC, NFPA and BS EN for fire protection, IPC/UPC or BS EN for plumbing, and IEC, BS 7671 or the NEC for electrical, alongside India's National Building Code where it applies.
Yes. We design remotely for international projects to the client's codes. Where the jurisdiction requires a locally licensed engineer to sign, that engineer of record reviews and stamps, and we support the submission.
Yes. The design is drawn in Revit from the start, so the model, drawings, schedules and quantities all come from the same coordinated source.
Engineering enquiry
Send a scope, a drawing set or the workflow you want this applied to. You will get a technical response on approach, disciplines, deliverables and what is realistically automatable — from an engineer, not a sales desk.